6ES7 315-2EH14-0AB0
|
General information
|
|
Hardware product version
|
01
|
Firmware version
|
V3.2
|
Engineering with
|
|
|
STEP7 V 5.5 or higher
|
Supply voltage
|
|
24 V DC
|
Yes
|
permissible range, lower limit (DC)
|
20.4 V
|
permissible range, upper limit (DC)
|
28.8 V
|
external protection for power supply lines (recommendation)
|
2 A min.
|
Mains buffering
|
|
-
Mains/voltage failure stored energy time
|
5 ms
|
|
1 s
|
Input current
|
|
Current consumption (rated value)
|
750 mA
|
Current consumption (in no-load operation), typ.
|
150 mA
|
Inrush current, typ.
|
4 A
|
I²t
|
1 A²·s
|
Power loss
|
|
Power loss, typ.
|
4.65 W
|
Memory
|
|
Type of memory
|
other
|
Work memory
|
|
|
384 kbyte
|
|
No
|
-
Size of retentive memory for retentive data blocks
|
128 kbyte
|
Load memory
|
|
|
Yes
|
|
8 Mbyte
|
-
Data management on MMC (after last programming), min.
|
10 a
|
Backup
|
|
|
Yes; Guaranteed by MMC (maintenance-free)
|
|
Yes; Program and data
|
CPU processing times
|
|
for bit operations, typ.
|
0.05 µs
|
for word operations, typ.
|
0.09 µs
|
for fixed point arithmetic, typ.
|
0.12 µs
|
for floating point arithmetic, typ.
|
0.45 µs
|
CPU-blocks
|
|
Number of blocks (total)
|
1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
|
DB
|
|
|
1 024; Number range: 1 to 16000
|
|
64 kbyte
|
FB
|
|
|
1 024; Number range: 0 to 7999
|
|
64 kbyte
|
FC
|
|
|
1 024; Number range: 0 to 7999
|
|
64 kbyte
|
OB
|
|
|
64 kbyte
|
|
1; OB 1
|
|
1; OB 10
|
-
Number of delay alarm OBs
|
2; OB 20, 21
|
-
Number of time interrupt OBs
|
4; OB 32, 33, 34, 35
|
-
Number of process alarm OBs
|
1; OB 40
|
|
3; OB 55, 56, 57
|
-
Number of isochronous mode OBs
|
1; OB 61
|
|
1; OB 100
|
-
Number of asynchronous error OBs
|
6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
|
-
Number of synchronous error OBs
|
2; OB 121, 122
|
Nesting depth
|
|
|
16
|
-
additional within an error OB
|
4
|
Counters, timers and their retentivity
|
|
S7 counter
|
|
|
256
|
|
|
|
Yes
|
|
0
|
|
255
|
|
Z 0 to Z 7
|
|
|
|
Yes
|
|
0
|
|
999
|
IEC counter
|
|
|
Yes
|
|
SFB
|
|
Unlimited (limited only by RAM capacity)
|
S7 times
|
|
|
256
|
|
|
|
Yes
|
|
0
|
|
255
|
|
No retentivity
|
|
|
|
10 ms
|
|
9 990 s
|
IEC timer
|
|
|
Yes
|
|
SFB
|
|
Unlimited (limited only by RAM capacity)
|
Data areas and their retentivity
|
|
retentive data area, total
|
All, 128 KB max.
|
Flag
|
|
|
2 048 byte
|
|
Yes; MB 0 to MB 2047
|
|
MB 0 to MB 15
|
|
8; 1 memory byte
|
Data blocks
|
|
|
1 024; Number range: 1 to 16000
|
|
64 kbyte
|
|
Yes; via non-retain property on DB
|
|
Yes
|
Local data
|
|
|
32 768 byte; Max. 2048 bytes per block
|
Address area
|
|
I/O address area
|
|
|
2 048 byte
|
|
2 048 byte
|
|
|
|
2 048 byte
|
|
2 048 byte
|
Process image
|
|
|
2 048 byte
|
|
2 048 byte
|
|
2 048 byte
|
|
2 048 byte
|
|
128 byte
|
|
128 byte
|
Subprocess images
|
|
-
Number of subprocess images, max.
|
1; With PROFINET IO, the length of the user data is limited to 1600 bytes
|
Digital channels
|
|
|
16 384
|
|
16 384
|
|
1 024
|
-
Outputs, of which central
|
1 024
|
Analog channels
|
|
|
1 024
|
|
1 024
|
|
256
|
-
Outputs, of which central
|
256
|
Hardware configuration
|
|
Expansion devices, max.
|
3
|
Number of DP masters
|
|
|
1
|
|
4
|
Number of operable FMs and CPs (recommended)
|
|
|
8
|
|
8
|
|
10
|
Rack
|
|
|
4
|
|
8
|
Time of day
|
|
Clock
|
|
-
Hardware clock (real-time clock)
|
Yes
|
-
battery-backed and synchronizable
|
Yes
|
|
10 s; Typ.: 2 s
|
|
6 wk; At 40 °C ambient temperature
|
-
Behavior of the clock following POWER-ON
|
Clock continues running after POWER OFF
|
-
Behavior of the clock following expiry of backup period
|
Clock continues to run with the time at which the power failure occurred
|
Operating hours counter
|
|
|
1
|
|
0
|
|
0 to 2^31 hours (when using SFC 101)
|
|
1 hour
|
|
Yes; Must be restarted at each restart
|
Clock synchronization
|
|
|
Yes
|
|
Yes
|
|
Yes
|
|
Yes; With DP slave only slave clock
|
|
Yes
|
|
Yes
|
|
Yes
|
|
Yes; As client
|
Digital inputs
|
|
Number of digital inputs
|
0
|
Digital outputs
|
|
Number of digital outputs
|
0
|
Analog inputs
|
|
Number of analog inputs
|
0
|
Analog outputs
|
|
Number of analog outputs
|
0
|
Interfaces
|
|
Number of USB interfaces
|
0
|
Number of parallel interfaces
|
0
|
Number of 20 mA interfaces (TTY)
|
0
|
Number of RS 232 interfaces
|
0
|
Number of RS 422 interfaces
|
0
|
Number of other interfaces
|
1; Ethernet, 2-port switch, 2*RJ45
|
1. Interface
|
|
Interface type
|
Integrated RS 485 interface
|
Physics
|
RS 485
|
isolated
|
Yes
|
Power supply to interface (15 to 30 V DC), max.
|
200 mA
|
Functionality
|
|
|
Yes
|
|
Yes
|
|
Yes
|
-
Point-to-point connection
|
No
|
MPI
|
|
|
12 Mbit/s
|
|
|
|
Yes
|
|
Yes
|
-
Global data communication
|
Yes
|
|
Yes
|
|
Yes
|
-
S7 communication, as client
|
No; but via CP and loadable FB
|
-
S7 communication, as server
|
Yes
|
DP master
|
|
|
12 Mbit/s
|
-
Number of DP slaves, max.
|
124
|
|
|
|
Yes
|
|
Yes
|
-
Global data communication
|
No
|
|
Yes; I blocks only
|
|
Yes
|
-
S7 communication, as client
|
No
|
-
S7 communication, as server
|
Yes
|
-
Equidistance mode support
|
Yes
|
|
Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
|
|
Yes
|
-
Activation/deactivation of DP slaves
|
Yes
|
-
Number of DP slaves that can be simultaneously activated/deactivated, max.
|
8
|
-
Direct data exchange (slave-to-slave communication)
|
Yes; As subscriber
|
|
Yes
|
|
|
|
2 kbyte
|
|
2 kbyte
|
|
|
|
244 byte
|
|
244 byte
|
DP slave
|
|
|
12 Mbit/s
|
-
Automatic baud rate search
|
Yes; only with passive interface
|
|
32
|
-
User data per address area, max.
|
32 byte
|
|
|
|
Yes
|
|
Yes; Only with active interface
|
-
Global data communication
|
No
|
|
No
|
|
Yes
|
-
S7 communication, as client
|
No
|
-
S7 communication, as server
|
Yes; Connection configured on one side only
|
-
Direct data exchange (slave-to-slave communication)
|
Yes
|
|
No
|
|
|
|
244 byte
|
|
244 byte
|
2. Interface
|
|
Interface type
|
PROFINET
|
Physics
|
Ethernet RJ45
|
isolated
|
Yes
|
integrated switch
|
Yes
|
Number of ports
|
2
|
automatic detection of transmission rate
|
Yes; 10/100 Mbit/s
|
Autonegotiation
|
Yes
|
Autocrossing
|
Yes
|
Change of IP address at runtime, supported
|
Yes
|
Media redundancy
|
|
|
Yes
|
-
Switchover time on line break, typ.
|
200 ms; PROFINET MRP
|
-
Number of stations in the ring, max.
|
50
|
Functionality
|
|
|
No
|
|
No
|
|
No
|
|
Yes; Also simultaneously with IO-Device functionality
|
|
Yes; Also simultaneously with IO Controller functionality
|
|
Yes
|
|
Yes; Via TCP/IP, ISO on TCP, and UDP
|
|
Yes
|
|
5
|
PROFINET IO Controller
|
|
|
100 Mbit/s
|
-
Number of connectable IO Devices, max.
|
128
|
-
Number of connectable IO Devices for RT, max.
|
128
|
|
128
|
-
Number of IO Devices with IRT and the option "high flexibility"
|
128
|
|
61
|
-
Number of IO Devices with IRT and the option "high performance", max.
|
64
|
|
64
|
|
Yes
|
|
Yes
|
-
Prioritized startup supported
|
Yes
|
-
Number of IO Devices, max.
|
32
|
-
Activation/deactivation of IO Devices
|
Yes
|
-
Number of IO Devices that can be simultaneously activated/deactivated, max.
|
8
|
-
IO Devices changing during operation (partner ports), supported
|
Yes
|
-
Number of IO Devices per tool, max.
|
8
|
-
Device replacement without swap medium
|
Yes
|
|
250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
|
|
250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, Technical Data" for more details)
|
|
|
|
Yes
|
|
Yes
|
|
Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32
|
|
Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO
|
|
Yes; Via TCP/IP, ISO on TCP, and UDP
|
|
|
|
2 kbyte
|
|
2 kbyte
|
-
User data consistency, max.
|
1 024 byte
|
PROFINET IO Device
|
|
|
|
|
Yes
|
|
Yes
|
|
Yes; With loadable FBs, max. configurable connections: 14, max. number of instances: 32
|
|
No
|
|
Yes; Via TCP/IP, ISO on TCP, and UDP
|
|
Yes
|
|
Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
|
|
Yes
|
-
Number of IO Controllers with shared device, max.
|
2
|
|
|
|
1 440 byte; Per IO Controller with shared device
|
|
1 440 byte; Per IO Controller with shared device
|
|
|
|
64
|
-
User data per submodule, max.
|
1 024 byte
|
PROFINET CBA
|
|
|
Yes
|
|
Yes
|
Open IE communication
|
|
-
Open IE communication, supported
|
Yes
|
-
Number of connections, max.
|
8
|
-
Local port numbers used at the system end
|
0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
|
-
Keep-alive function, supported
|
Yes
|
Isochronous mode
|
|
Isochronous mode (application synchronized up to terminal)
|
Yes; Via PROFIBUS DP or PROFINET interface
|
Communication functions
|
|
PG/OP communication
|
Yes
|
Data record routing
|
Yes
|
Global data communication
|
|
|
Yes
|
|
8
|
-
Number of GD packets, max.
|
8
|
-
Number of GD packets, transmitter, max.
|
8
|
-
Number of GD packets, receiver, max.
|
8
|
|
22 byte
|
-
Size of GD packet (of which consistent), max.
|
22 byte
|
S7 basic communication
|
|
|
Yes
|
|
76 byte
|
-
User data per job (of which consistent), max.
|
76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
|
S7 communication
|
|
|
Yes
|
|
Yes
|
|
Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
|
|
See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
|
S5 compatible communication
|
|
|
Yes; via CP and loadable FC
|
Open IE communication
|
|
|
Yes; via integrated PROFINET interface and loadable FBs
|
-
Number of connections, max.
|
8
|
-
Data length for connection type 01H, max.
|
1 460 byte
|
-
Data length for connection type 11H, max.
|
32 768 byte
|
-
Several passive connections per port, supported
|
Yes
|
|
Yes; via integrated PROFINET interface and loadable FBs
|
-
Number of connections, max.
|
8
|
|
32 768 byte
|
|
Yes; via integrated PROFINET interface and loadable FBs
|
-
Number of connections, max.
|
8
|
|
1 472 byte
|
Web server
|
|
|
Yes
|
|
5
|
|
Yes
|
PROFINET CBA (at set setpoint communication load)
|
|
-
Setpoint for the CPU communication load
|
50 %
|
-
Number of remote interconnection partners
|
32
|
-
Number of functions, master/slave
|
30
|
-
Total of all master/slave connections
|
1 000
|
-
Data length of all incoming connections master/slave, max.
|
4 000 byte
|
-
Data length of all outgoing connections master/slave, max.
|
4 000 byte
|
-
Number of device-internal and PROFIBUS interconnections
|
500
|
-
Data length of device-internal und PROFIBUS interconnections, max.
|
4 000 byte
|
-
Data length per connection, max.
|
1 400 byte
|
-
Remote interconnections with acyclic transmission
|
|
-
Sampling frequency: Sampling time, min.
|
500 ms
|
-
Number of incoming interconnections
|
100
|
-
Number of outgoing interconnections
|
100
|
-
Data length of all incoming interconnections, max.
|
2 000 byte
|
-
Data length of all outgoing interconnections, max.
|
2 000 byte
|
-
Data length per connection, max.
|
1 400 byte
|
-
Remote interconnections with cyclic transmission
|
|
-
Transmission frequency: Transmission interval, min.
|
10 ms
|
-
Number of incoming interconnections
|
200
|
-
Number of outgoing interconnections
|
200
|
-
Data length of all incoming interconnections, max.
|
2 000 byte
|
-
Data length of all outgoing interconnections, max.
|
2 000 byte
|
-
Data length per connection, max.
|
450 byte
|
-
HMI variables via PROFINET (acyclic)
|
|
-
Number of stations that can log on for HMI variables (PN OPC/iMap)
|
3; 2x PN OPC/1x iMap
|
|
500 ms
|
|
200
|
-
Data length of all HMI variables, max.
|
2 000 byte
|
-
PROFIBUS proxy functionality
|
|
|
Yes
|
-
Number of linked PROFIBUS devices
|
16
|
-
Data length per connection, max.
|
240 byte; Slave-dependent
|
Number of connections
|
|
|
16
|
-
usable for PG communication
|
15
|
-
reserved for PG communication
|
1
|
-
adjustable for PG communication, min.
|
1
|
-
adjustable for PG communication, max.
|
15
|
-
usable for OP communication
|
15
|
-
reserved for OP communication
|
1
|
-
adjustable for OP communication, min.
|
1
|
-
adjustable for OP communication, max.
|
15
|
-
usable for S7 basic communication
|
14
|
-
reserved for S7 basic communication
|
0
|
-
adjustable for S7 basic communication, min.
|
0
|
-
adjustable for S7 basic communication, max.
|
14
|
-
usable for S7 communication
|
14
|
-
reserved for S7 communication
|
0
|
-
adjustable for S7 communication, min.
|
0
|
-
adjustable for S7 communication, max.
|
14
|
-
total number of instances, max.
|
32
|
|
X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.
|
S7 message functions
|
|
Number of login stations for message functions, max.
|
16; Depending on the configured connections for PG/OP and S7 basic communication
|
Process diagnostic messages
|
Yes
|
simultaneously active Alarm-S blocks, max.
|
300
|
Test commissioning functions
|
|
Status block
|
Yes; Up to 2 simultaneously
|
Single step
|
Yes
|
Number of breakpoints
|
4
|
Status/control
|
|
|
Yes
|
|
Inputs, outputs, memory bits, DB, times, counters
|
-
Number of variables, max.
|
30
|
-
of which status variables, max.
|
30
|
-
of which control variables, max.
|
14
|
Forcing
|
|
|
Yes
|
|
Inputs, outputs
|
-
Number of variables, max.
|
10
|
Diagnostic buffer
|
|
|
Yes
|
|
500
|
|
No
|
|
100; Only the last 100 entries are retained
|
-
Number of entries readable in RUN, max.
|
499
|
|
Yes; From 10 to 499
|
|
10
|
Service data
|
|
|
Yes
|
Ambient conditions
|
|
Operating temperature
|
|
|
0 °C
|
|
60 °C
|
Configuration
|
|
Configuration software
|
|
|
Yes; V5.5 or higher
|
Programming
|
|
|
see instruction list
|
|
8
|
|
see instruction list
|
-
System function blocks (SFB)
|
see instruction list
|
|
|
|
Yes
|
|
Yes
|
|
Yes
|
|
Yes
|
|
Yes
|
|
Yes
|
|
Yes
|
Know-how protection
|
|
-
User program protection/password protection
|
Yes
|
|
Yes; With S7 block Privacy
|
Dimensions
|
|
Width
|
40 mm
|
Height
|
125 mm
|
Depth
|
130 mm
|
Weights
|
|
Weight, approx.
|
340 g
|