详细介绍:
Performance性能
1 Standard Test Condition标准测试条件
The tested battery must be a new battery with production time less than one month, the charge and discharge cycle less than 5 times. Unless there were other particular requirements, the testing condition for this specification is: temperature 15~35℃, relative humidity 45%~75%, atmospheric Pressure 86~106kPa.
测试电池必须是本公司出厂时间不超过一个月的新电池,且电池未进行过五次以上充放电循环。除非其它特殊要求,本产品规格书中的测试条件为:温度15~35℃,相对湿度45%~75%的条件,大气压力86~106kPa。
2 Measurement Apparatus Request测试设备要求
(1)The dimension measurement shall be implemented by instruments with equal or more precision scale of 0.01mm.
测量尺寸的仪器精度应大于等于0.01mm。
(2)万用表测量电压及电流的准确度应不低于0.5级,测量电压时内阻不应小于10kΩ/V。
The precision of multimeter should be not low than 0.5 class, inner impedance not less than 10 kΩ/V.
(3)内阻测试仪测量原理应为交流阻抗法(1kHz NLCR)。
Impedance shall be measured by a sinusoidal alternating current method(AC 1kHz LCR meter).
(4)电池测试系统的电流精度应在±0.1%以上,恒压精度±0.5%,计时精度不低于±0.1%。
Current test precision rate above 0.1%, CV precision rate ±0.5%, timing precision rate no less than ±0.1%.
(5)测量温度的仪表准确度应不低于±0.5℃。
Thermometer precision rate no less than ±0.5℃.