当前位置:首页 >> 产品展示 >> 电子 >> 电源管理 >>瑞士固特(GUTOR)ups电源
瑞士固特(GUTOR)ups电源放大图片

产品价格:100   元(人民币)
上架日期:2015年7月23日
产地:瑞士
发货地:北京  (发货期:当天内发货)
供应数量:不限
最少起订:1台
浏览量:726
  暂无相关下载
其他资料下载:

         
中企建业电源系统(北京)有限公司

点击这里给我发消息
  详细说明  
品牌:固特ups电源产地:瑞士
价格:100人民币/台规格:Gutor SDC - DC Supply Systems/Chargers

简要说明:固特ups电源牌的瑞士固特(GUTOR)ups电源产品:估价:100,规格:Gutor SDC - DC Supply Systems/Chargers,产品系列编号:齐全

详细介绍:

  

瑞士固特(GUTOR)ups电源

Swiss UPS power supply, professional industrial grade UPS power supply

 

Gutor SDC - DC Supply Systems/Chargers

Industrial thyristor rectifier with broad application areas



 

Industrial thyristor rectifier from 25- 1200ADC and higher

With its broad range of possible DC voltages, the SDC is very flexible and can meet specific requirements and a wide range of autonomy times. Similar to the other products built on the xxW platform (PxW and WxW), the SDC will withstand the harshest environmental conditions. The firmware is certified according to IEC60880 for NPP (Nuclear Power Plant) applications.

This product is best in its class, because it benefits from our focus on quality and attention to detail.
Benefits
Flexibility
Due to the independent modules, the UPS can be sized individually based on customer requirements.

NPP qualified
The firmware is certified according to IEC 60880 for third party, and the components are withstanding applicable seismic requirements.

Proven reliability
Best in class Mean Time Between Failures (MTBF) within a long product lifetime with minimal servicing required. Over 20,000 systems installed worldwide with excellent quality records.
Applications
- Nuclear Power Plants (NPP)
- Oil & Gas, Petrochemical (onshore, offshore, pipelines, refining, FPSO)
- Power generation, including transmission and distribution
- Chemical industry
- Other industrial applications

Schneider electric Gutor production line in Xiamen, deep localized new future
News
Xiamen, China, November 6, Schneider Electric IT business department gutor summit partners and new production line inauguration was grandly held recently in Xiamen Yi Peisi electrical facilities Co., Ltd., ITB gutor China region general manager Wang Xiaojun, gutor ITB Asia Pacific Sales Director Thierry Bayle, Schneider's global supply chain of vice president of division of China of Bertrand Chapuy, and Schneider's global supply chain Xiamen factory general manager Katherine Ye attended the event and with China core partners gather.
The gutor will be the new production line from Beijing to the relocation of the Xiamen is Schneider Electric for better integration of resources, reduce costs, an important measure to improve production efficiency, will provide customers with effective relationship delivery cycle and provide more localized product selection, so as to better exploit the potential customer market, enhance the market share. On the summit, Schneider Electric and partners together on how to further enhance the customer satisfaction has carried on the thorough discussion, and strengthen the Schneider Electric will continue for the partners to provide more excellent products and service philosophy, thus better work together to explore and develop nuclear power, oil, petrochemical, and other areas of business growth potential.
Schneider Electric IT business gutor China region general manager Wang Xiaojun said: "Schneider Electric always pay attention to the integration of resources and utilization, and pay attention to according to the market reaction to make self adjustment so that their continued to maintain the leading position in the industry. The new production line of Gutor Xiamen, Schneider Electric is an important strategic adjustment. Gutor combined with the characteristics of localization in China, formulates the corresponding development direction and strategy, including further enhance in nuclear power, petroleum, petrochemical, and other areas of brand share, better with localized resources to enhance the advantage of competition, the development of specialized core partners to in the industry such as the promotion of specific target to better service customers in China, "he said.
Schneider Electric has advanced gutor industrial grade UPS Technology, is one of the world's leading industrial grade UPS system manufacturer, based on high technology standards from the installation, maintenance, training and other services solutions. UPS Gutor system and service system developed in Switzerland has been widely used in the fields of energy regeneration, natural gas, chemical engineering and other fields, as well as nuclear power plants and conventional power plants. In China, gutor by have strong technical support, perfect professional customized programs and senior service team, to meet customers in China for the professional and technical, harsh application environment and the special custom high requirements, providing products and services with high quality reliability and stability of the.
About Schneider electric
Provide total solutions for the global specialist in energy management, Schneider Electric in more than 100 countries energy efficiency and infrastructure, industrial control, data centers and networks, buildings and residential market, which in the energy efficiency and infrastructure, industrial process control, building automation, data center and network market in a leading position in the world, in residential applications also have strong market power. Committed to providing customers with safe, reliable, efficient, economical and environmentally friendly energy efficiency, Schneider electric 2013 sales of 24000000000 euros, the group has more than 150000 employees. Schneider electric to help you - use their effect, to enjoy the!

 
SYSTEM DESIGN, CHARACTERISTICS AND BENEFITS
   UPS technology from GUTOR is designed to satisfy requirements with regard to functionality, security and reliability – the main interests of our customers. It has great system flexibility in terms of system design and meets the technical specifications of customers. We produce all our products to conform to internationally and nationally recognised standards and guarantee the highest levels of quality with ISO9001:2000. Some of the main functions and benefits of the design are as follows:    Clear operating and monitoring of the functioning  Safe operation and maintenance   High level of protection against environmental effects  Highest level of system availability and reliability  Modular Design  Our system design is modular It enables access to all components from the front as well as from the top. A typical GUTOR UPS unit contains a separate connection field with the input switch and the manual bypass switch. Some components are installed on shelves or hinged panel for
simple maintenance.  High integrated control logic  All systems are fitted with microprocessor driven controls, which enable digital processing and the adjustment of all parameters. In order to guarantee reliable functioning, two independent sources – the mains
and the battery – supply the controller with power.


   UPS SYSTEM - DESCRTPTION   BYPASS  BYPASS
– TRANSFORMER AND STABILISER  The traditional UPS system contains the following components: Thyristor, rectifier, inverter and static switching module, a manual bypass switch, transformer, controller as well as a human-machine interface (on the control unit) with screen.
   If a system is in bypass mode, the voltage from the bypass mains is supplied directly. Switching over between normal supply and bypass mode can be done manually. Should the supply from the inverter be insufficient, the switchover takes place automatically and without disrupting the voltage.  If there are differences between the input voltage and the output voltage in the bypass network, some systems include a bypass transformer or stabiliser. The transformers adapts the input voltage to the output voltage; the stabiliser compensates for the network fluctuations and keeps the output voltage stable.     Typical installation of high power stabilizator with Controller Box
HUMAN-MACHINE INTERFACE  INTELLIGENT SYSTEM VENTILATION  STANDARDS & QUALITY  BATTERIES  AC and DC systems from GUTOR are fitted with a self-explanatory control unit, a flexible human-machine interface, which displays and monitors the system parameters. The control unit is divided into four parts. 1. The user-specific mimic diagram displays the current mode of operation and gives information on which part of the system is currently supplying the voltage and which is in standby mode.  2.System main control buttons with lamp test facilities.   3. The display unit consists of an LCD display, which displays the event recorder, the alarm list, measurements and the mode of operation, and which also has an alarm LED, an acoustic alarm and a keypad.  4.
The alarm display has LEDs, which display system-specific alarm incidents.   GUTOR offers the redundant ventilation concept, “N+1” as standard. In the event that one of the fans fails, the two remaining fans are sufficient to maintain the cooling of the system. With the help of an internal speed sensor, the revolutions of each of the individual fans are also monitored. Should the speed fall below one of the pre-defined tolerance values, an alarm is triggered. The fans can be changed during normal system operation, without any risk to staff or the load.  THAT ARE RECOGNISED WORLDWIDE   GUTOR supplies products that are designed and manufactured based on standards that are recognised worldwide, such as EN, IEC, IEEE,
VDE, SEV, NEMA, ANSI, CSA, UL and FCC.  Internal and external checks guarantee high standards of quality. Our in-house quality management as well as the Veritas office – an external inspection organisation, carry out these checks. GUTOR’s systems and processes undergo customer audits and therefore guarantee qualification for special applications. Customers and inspectors have
access to all available reports.  THE APPROPRIATE TYPE OF BATTERY FOR YOUR REQUIREMENTS   Batteries are a central element in the design of UPS systems. They store energy that is required to guarantee the necessary energy during a power cut. The correct choice of battery is therefore crucial. GUTOR advises and supports clients in all their questions and decisions with regard to the dimensioning of the various types of batteries. We calculate the size of battery based on the individual load profile in accordance with IEEE standards. GUTOR has many years of  experience in close cooperation with well-known battery manufacturers
as well as in advice and calculations for optimal batteries for the most
diverse applications. GUTOR systems are designed for lead as well as nickel-cadmium batteries.  CALCULATING THE SIZE OF BATTERIES   GUTOR advises and supports clients in all their questions and decisions with regard to the dimensioning of the various types of batteries. We calculate the size of battery based on the individual load profile in
accordance with IEEE standards.  BATTERY MONITORING   In the event of a power cut, it is important that back-up batteries function optimally. Battery monitoring is therefore an effective solution to guarantee the efficiency of batteries and their full capacity. Also, monitoring guarantees the functioning of the entire installation. GUTOR systems have a built-in capacity function for safe discharging and charging tests for batteries as standard. These can be activated via the keypad on the control unit. When the test is started up, the system switches over to battery supply. The commutator remains in standby mode during this period, to enable careful start-up should this be necessary. The entire duration of the discharging is saved in the system for statistical purposes.    Build in Battery Capacity Test
   GUTOR also offers an extended battery monitoring system (EBM) as an option, which can be integrated into any system. In comparison with the capacity test, the EBM has different benefits.

 


该公司其他信息
最新供求信息 企业产品推荐

暂无产品
  在线询盘/留言 请仔细填写准确及时的联系到你!  
您的姓名:
* 预计需求数量: *
联系手机:
*  移动电话或传真:
电子邮件:
* 所在单位:
咨询内容:
*
           您要求厂家给您提供:
  • 规格,型号
  • 价格及付款条件
  • 产品目录
  • 最低订货量
  • 运送资料
  • 提供样本
  • 库存情况
  • 包装材料