【广州★洋奕】完美的服务秉承中华名族“卓越的品质,在直接用户及广大经销商中具有良好的口碑,同时L6D-C3-10KG-0.4B称重传感器相比同行企业,取得了令人瞩目的成绩,是从选配、安装、维护一站式服务的企业,价格实惠,高品质产品,周到的服务,是您放心的选择!
微型称重传感器:
Q45X8X6-7.5g,Q45X8X6,200,300g,Q45X10X6,500,750g
Q84X5X12-05,20,30,50,100,g, Q70X5X9-H,20,30,50,100,200,g
004-Z1,0.3,0.6,0.75,1.5,3,KG Q47X20X6.6,100,120,300,500,1000,g
45X6X6-7.5g,150,g 2N,40KG 2F,20KG 2D,24KG
2C,10KG 2A/2A-K,15,50,LB 1Z,5-30KG 1X,300,500,600,g,
1V3-350,5,10,25,KG CF-1,1,KG 1T-M,150,KG
1R1-K,0.6,1,2,3,5,6,KG 1P,40,75,KG HM,0.5,1,5,8,20,,KG
JB01-2,JB01-3,JB01-4,JB01-6,JB01-8 JB02-2,JB02-3,JB02-4,
JB05A-4,JB05A-6,JB05A-8, JB06-2,JB06-3,JB06-4,JB06-6,JB06-8
JB07-2,JB07-3,JB07-4, FD-3,FD-4,FD-5
S型梁式称重传感器:
H3-C3-25kg-3B 0.025/0.05/0.1/0.15/0.2/0.25/0.3/0.5/0.6/7.5/10/15/20/30t
H3F-C3-1-6t-6B 0.1/0.25/0.5/0.75/1/1.5/2/2.5/5t
B3G-C3-50kg-6B 0.05/0.1/0.25/0.5/1/2.5/5/7.5/10t
H3G-c3-100kg-3B 0.05/0.1/0.2/0.25/0.5/1/2.5/5/7.5t
BM3-C3-500kg-4B 0.5/1/2/3/4/5/6/7.5t
单点式称重传感器L6B、L6D、L6E、L6E3、L6F、L6G、L6J、L6H5:
2.系统刚度
①承载体的刚度
承载体刚度是指支撑承载器的结构部分的刚度,如果承载体变形较大,会造成称重传感器承受分力,从而影响称量的准确度。一般选用剪切梁传感器的系统、抗偏载能力较高,可以允许刚度稍差点,选用柱式传感器的系统、抗偏载能力较低,必须使承载体刚度很好。
另外,当在一个承载体上安装多套称量系统时,承载体的刚度一定要能保证各套称量系统之间不干涉各自的正常称量。
②承载器的刚度
一般承载器在没有考虑称量要求时,自身用的材料比较薄,易产生形变。当要改造成称量系统时,这样就会直接影响到称量准确度,这时应当对承载器的支撑部位进行加强。
3.检验方法
任何一套称量系统改造好以后,必然供需对方进行验收,这个问题在签订改造合同时就应考虑好的。如果需方提出自己进行,只要供方提供称重模块和称重显示器,就可以了。如果需方提出双方交接,必须在保证达到合同中规定的称量准确度时,在合同中就应将检验方法和相关费用考虑进去了。
目前,这种称量系统有两种检验方法,一种是替代法,一种是比对法。
①替代法
由承载器原设计时没有考虑作为称量器具,在其外部没有设计按放标准砝码的位置,往往只能少量标准砝码来检验,而少量标准砝码又不能保证称量系统满量程的准确性,这样只能使用其它恒定载荷替代标准砝码,一次次反复的使用有限砝码和恒定载荷替代,从零点开始,一直检验到使用的最大载荷量。
使用替代法的关键问题是,要求被测试装置的重复性必须高。
②比对法
是选用在标准测试装置上标定好的一套称重传感器和称重显示器,与称量系统上的称重传感器和称重显示器相比较。使用比对法的关键问题是,要求在使用现场预先设计可安装标准装置的位置,所以使用比对法检验最好是在设计称量系统时就着手进行。