Display
|
|
|
|
|
with display
|
Yes; The display is bright at temperatures below 0 °C and dark at temperatures over +55 °C. This procedure is self-reversing on returning to the standard temperature range (0 °C to +55 °C).
|
Yes; The display is bright at temperatures below 0 °C and dark at temperatures over +55 °C. This procedure is self-reversing on returning to the standard temperature range (0 °C to +55 °C).
|
Yes; The display is bright at temperatures below 0 °C and dark at temperatures over +55 °C. This procedure is self-reversing on returning to the standard temperature range (0 °C to +55 °C).
|
Yes; The display is bright at temperatures below 0 °C and dark at temperatures over +55 °C. This procedure is self-reversing on returning to the standard temperature range (0 °C to +55 °C).
|
Installation type/mounting
|
|
|
|
|
Mounting
|
on 35 mm DIN rail, 4 spacing units wide
|
on 35 mm DIN rail, 4 spacing units wide
|
on 35 mm DIN rail, 4 spacing units wide
|
on 35 mm DIN rail, 4 spacing units wide
|
Supply voltage
|
|
|
|
|
Rated value (DC)
|
|
|
|
|
|
|
Yes
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
|
|
|
Yes
|
|
|
|
|
Yes
|
permissible range, lower limit (DC)
|
20.4 V; 22 V @ >55 °C
|
10.8 V; 11 V @ >55 °C
|
20.4 V; 22 V @ >55 °C
|
100 V
|
permissible range, upper limit (DC)
|
28.8 V; 27.5 V @ >55 °C
|
28.8 V; 27.5 V @ >55 °C
|
28.8 V; 27.5 V @ >55 °C
|
253 V
|
Rated value (AC)
|
|
|
|
|
|
|
|
Yes
|
|
|
|
|
|
Yes
|
|
|
|
|
Yes
|
Time of day
|
|
|
|
|
Time switching clocks
|
|
|
|
|
|
190
|
8
|
|
|
|
80 h
|
80 h
|
80 h
|
80 h
|
Digital inputs
|
|
|
|
|
Number of digital inputs
|
8; Of which 4 can be used in analog mode (0 to 10 V)
|
8; Of which 4 can be used in analog mode (0 to 10 V)
|
8
|
8
|
Digital outputs
|
|
|
|
|
Number of digital outputs
|
4; Transistor
|
4; Relays
|
4; Relays
|
4; Relays
|
Short-circuit protection
|
Yes; electrical (1 A)
|
No; external fusing necessary
|
No; external fusing necessary
|
No; external fusing necessary
|
Output current
|
|
|
|
|
|
0.3 A; 0.2 A @ > 55 °C; 0.3 A @ > 55 °C & < 15 s
|
|
|
|
Relay outputs
|
|
|
|
|
Switching capacity of contacts
|
|
|
|
|
|
|
3 A; 1 A per relay @ > 55 °C; 3 A per relay @ > 55 °C & < 15 s
|
3 A; 1 A per relay @ > 55 °C; 3 A per relay @ > 55 °C & < 15 s
|
3 A; 1 A per relay @ > 55 °C; 3 A per relay @ > 55 °C & < 15 s
|
|
|
10 A; 3 A per relay @ > 55 °C; 10 A per relay @ > 55 °C & < 15 s
|
10 A; 3 A per relay @ > 55 °C; 10 A per relay @ > 55 °C & < 15 s
|
10 A; 3 A per relay @ > 55 °C; 10 A per relay @ > 55 °C & < 15 s
|
EMC
|
|
|
|
|
Emission of radio interference acc. to EN 55 011
|
|
|
|
|
|
Yes; Radio interference suppression according to EN55011, Limit value Class B
|
Yes
|
Yes
|
Yes
|
Degree and class of protection
|
|
|
|
|
Degree of protection acc. to EN 60529
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
Standards, approvals, certificates
|
|
|
|
|
CSA approval
|
No
|
No
|
No
|
No
|
UL approval
|
Yes; file: E120869 // Tmax = 55 °C
|
Yes; file: E120869 // Tmax = 55 °C
|
Yes; file: E120869 // Tmax = 55 °C
|
Yes; file: E120869 // Tmax = 55 °C
|
FM approval
|
No
|
No
|
No
|
No
|
developed in accordance with IEC 61131
|
Yes
|
Yes
|
Yes
|
Yes
|
according to VDE 0631
|
Yes
|
Yes
|
Yes
|
Yes
|
Marine approval
|
|
|
|
|
|
No
|
No
|
No
|
No
|
Ambient conditions
|
|
|
|
|
Ambient temperature during operation
|
|
|
|
|
|
-25 °C; = Tmin
|
-25 °C; = Tmin
|
-25 °C; = Tmin
|
-25 °C; = Tmin
|
|
70 °C; = Tmax; 55 °C @ UL/cUL use
|
70 °C; = Tmax; 55 °C @ UL/cUL use
|
70 °C; = Tmax; 55 °C @ UL/cUL use
|
70 °C; = Tmax; 55 °C @ UL/cUL use
|
Extended ambient conditions
|
|
|
|
|
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m)
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)
|
Relative humidity
|
|
|
|
|
|
100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions)
|
100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions)
|
100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions)
|
100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions)
|
Resistance
|
|
|
|
|
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
|
|
Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3C4 incl. salt spray. The supplied connector covers must remain on the unused interfaces during operation!
|
|
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
|
Dimensions
|
|
|
|
|
Width
|
72 mm
|
72 mm
|
72 mm
|
72 mm
|
Height
|
90 mm
|
90 mm
|
90 mm
|
90 mm
|
Depth
|
55 mm
|
55 mm
|
55 mm
|