详细介绍:
倍加福P+F NCB50-FP-E34-C-P3-V1接近开关原理倍加福传感器官网 倍加福中国官方网站 施耐德接近开关选型 接近开关 倍加福接近开关选型
倍加福 倍加福官网 接近开关原理 倍加福接近开关样本 倍加福接近开关型号
NCB50-FP-E34-C-P3-V1 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 3-wire, Installation: flush, Type of voltage: DC
Inductive sensor
NCB50-FP-Z2-P1 Series: Rectangular type, Housing material: PBT, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 2-wire, Installation: flush, Type of voltage: DC
Inductive sensor
NCB50-FP-Z4-V1 Series: Rectangular type, Housing material: PBT, Rated operating distance: 50 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 2-wire, Installation: flush, Type of voltage: DC
Inductive sensor
NCB50-FP-Z5-V1 Series: Rectangular type, Housing material: PBT, Rated operating distance: 50 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 2-wire, Installation: flush, Type of voltage: DC
Inductive sensor
厂家_
安装注意事项
选择指南订购信息
上海创弗实业有限公司
电话:18001664790
工作QQ:1816120794
邮件:cfyysh@163.com
公司网址:http://www.chuangfush.com我们公司专业:做罗斯蒙特变送器和横河变送器 ,Rosemount Analytical分析仪器技术支持,选型调式 等售后服务。
Rosemount Analytical
NCN40+U1+N0 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NCN40+U1+N0-V1 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NCN40+U1+U Series: VariKont , Housing material: PBT, Rated operating distance: 40 mm, Switching element function: AC/DC Make/Break function, Connection type: terminal compartment, Output type: 2-wire, Installation: not embeddable, Kind of voltage: UC
Inductive sensor
NCN40+U1+Z2 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor倍加福P+F NCB50-FP-E34-C-P3-V1接近开关原理
NCN40+U4+N0-V1 Series: VariKont ®, Housing material: PBT/metal, Rated operating distance: 40 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NCN40+U4+U Series: VariKont ®, Housing material: PBT/metal, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 2-wire, Installation: non-flush, Type of voltage: UC
Inductive sensor
NCN40-FP-W-T-P1 Series: Rectangular type, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 2-wire, Installation: not embeddable, Type of voltage: AC
Inductive sensor
NCN40-FP-W-T-P4 Series: Rectangular type, Housing material: PBT/base of metal, Rated operating distance: 40 mm, Switching element function: AC Make/Break function, Connection type: terminal compartment, Output type: 2-wire, Installation: not embeddable, Kind of voltage: AC
Inductive sensor
NCN40-L2-N0-V1 Series: VariKont L ®, Housing diameter: , Housing material: PA, Rated operating distance: 40 mm, Connection type: Connector M12 x 1 , 4-pin, Installation: non-flush, Type of voltage: DC, ATEX 3G
Inductive sensor
NCN50-FP-A2-P1 Housing material: PBT, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 4-wire, Installation: not embeddable, Type of voltage: DC
Inductive sensor
NCN50-FP-A2-P1-3G-3D Housing material: PBT, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 4-wire, Installation: not embeddable, Type of voltage: DC, ATEX 3G
Inductive sensor
NCN50-FP-A2-P1-V1 Housing material: PBT, Rated operating distance: 50 mm, Connection type: Device connector M12 x 1 , 4-pin, Output type: 4-wire, Installation: not embeddable, Type of voltage: DC
Inductive sensor
NCN50-FP-A2-P3 Housing material: PBT/base of metal, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 4-wire, Installation: not embeddable, Type of voltage: DC
Inductive sensor
NCN50-FP-A2-P4 Housing material: PBT/base of metal, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 4-wire, Installation: not embeddable, Type of voltage: DC
Inductive sensor
NCN50-FP-N0-P1 Series: Rectangular type, Housing material: PBT, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor倍加福P+F NCB50-FP-E34-C-P3-V1接近开关原理
NCN50-FP-N0-P4 Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 2-wire, Installation: not embeddable, Type of voltage: DC
Inductive sensor
NCN50-FP-N0-P4-V1 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NCN50-FP-W-P1 Series: Rectangular type, Housing material: PBT, Rated operating distance: 50 mm, Switching element function: AC Make/Break function, Connection type: terminal compartment, Output type: 2-wire, Installation: not embeddable, Kind of voltage: AC
Inductive sensor
NCN50-FP-W-P2 Series: Rectangular type, Housing material: PBT, Rated operating distance: 50 mm, Switching element function: AC Make/Break function, Connection type: terminal compartment, Output type: 2-wire, Installation: not embeddable, Kind of voltage: AC
Inductive sensor
NCN50-FP-W-P4 Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 2-wire, Installation: not embeddable, Type of voltage: AC
Inductive sensor
NCN50-FP-W-P4-BHMS3-N.O. Series: Rectangular type, Housing material: PBT/base of metal, Rated operating distance: 50 mm, Connection type: 7/8"-16 UN , 3-pin, Output type: 2-wire, Installation: not embeddable, Type of voltage: AC
Inductive sensor
NCN50-FP-Z2-P1 Housing material: PBT, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 2-wire, Installation: not embeddable, Type of voltage: DC
Inductive sensor
NCN50-FP-Z2-P4 Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 2-wire, Installation: not embeddable, Type of voltage: DC
Inductive sensor
NCN50-FP-Z2-P4-V1 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NCN50-FP-Z3-P4-V1 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NCN50-FP-Z4-V1 Series: Rectangular type, Housing material: PBT, Rated operating distance: 50 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NEN40+U4+U Series: VariKont-Gehäuse, Housing material: PBT/metal, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 2-wire, Installation: non-flush
Inductive sensor
NEN40-30GM60-E0 Series: Cylindrical type, Housing diameter: 30 mm, Housing material: chromium plated brass, Rated operating distance: 40 mm, Connection type: cable PVC , 2 m, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NEN40-30GM60-E0-V1 Series: Cylindrical type, Housing diameter: 30 mm, Housing material: chromium plated brass, Rated operating distance: 40 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NEN40-30GM60-E2 Series: Cylindrical type, Housing diameter: 30 mm, Housing material: chromium plated brass, Rated operating distance: 40 mm, Connection type: cable PVC , 2 m, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NEN40-30GM60-E2-V1 Series: Cylindrical type, Housing diameter: 30 mm, Housing material: chromium plated brass, Rated operating distance: 40 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NEN40-30GM60-E3-V1 Series: Cylindrical type, Housing diameter: 30 mm, Housing material: chromium plated brass, Rated operating distance: 40 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U1+A Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U1+A2 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U1+A2-T Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 4-wire, Installation: not embeddable, Type of voltage: DC
Inductive sensor
NJ40+U1+A2-T-V1 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: connector M12 x 1, 4-pin, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U1+A2-V1 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: connector M12 x 1, 4-pin, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U1+E Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U1+E1 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U1+E2 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U1+E2-C Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U1+E2-T-V1 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: connector M12 x 1, 4-pin, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U1+E2-V1 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: connector M12 x 1, 4-pin, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U1+E3 Series: VariKont , Housing material: PBT, Rated operating distance: 40 mm, Switching element function: PNP Break function, Connection type: terminal compartment, Output type: 3-wire, Installation: not embeddable, Kind of voltage: DC
Inductive sensor
NJ40+U1+N Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U1+W Series: VariKont , Housing material: PBT, Rated operating distance: 40 mm, Switching element function: AC Make/Break function, Connection type: terminal compartment, Output type: 2-wire, Installation: not embeddable, Kind of voltage: AC
Inductive sensor
NJ40+U1+W4 Series: VariKont , Housing material: PBT, Rated operating distance: 40 mm, Switching element function: AC Make/Break function, Connection type: terminal compartment, Output type: 4-wire, Installation: not embeddable, Kind of voltage: AC
Inductive sensor
NJ40+U10+E2 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U2+A2 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: terminal compartment, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U2+N Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U2+W Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 2-wire, Installation: not embeddable, Type of voltage: AC
Inductive sensor
NJ40+U4+A Series: VariKont ®, Housing material: PBT/metal, Rated operating distance: 40 mm, Connection type: terminal compartment, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U4+A2 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U4+A2-V1 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: V1 connector (M12 x 1), 4-pin, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U4+DW2-1 Series: VariKont ®, Housing material: PBT/metal, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 3-wire, Installation: non-flush, Type of voltage: AC
Inductive sensor
NJ40+U4+DW2-10 Series: VariKont ®, Housing material: PBT/metal, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 3-wire, Installation: non-flush, Type of voltage: AC
Inductive sensor
NJ40+U4+E Series: VariKont ®, Housing material: PBT/metal, Rated operating distance: 40 mm, Connection type: terminal compartment, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U4+E-V1 Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: V1 connector (M12 x 1), 4-pin, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U4+E2 Series: VariKont ®, Housing material: PBT/metal, Rated operating distance: 40 mm, Connection type: terminal compartment, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U4+E2-V1
Inductive sensor
NJ40+U4+N Series: VariKont ®, Housing material: PBT/metal, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40+U4+W Series: VariKont-Gehäuse, Housing material: PBT/metal, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 2-wire, Installation: non-flush, Type of voltage: AC
Inductive sensor
NJ40+U4+W-BHMS3-N.O. Series: VariKont ®, Housing material: PBT, Rated operating distance: 40 mm, Connection type: Quick disconnect type BHMS3, Output type: 2-wire, Installation: non-flush, Type of voltage: AC
Inductive sensor
NJ40+U4+W-T Series: VariKont , Housing material: PBT, Rated operating distance: 40 mm, Switching element function: AC Make/Break function, Connection type: terminal compartment, Output type: 2-wire, Installation: not embeddable, Kind of voltage: AC
Inductive sensor
NJ40+U4+W4-Y12206 Series: VariKont ®, Housing material: PBT/metal, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 4-wire, Installation: not embeddable, Type of voltage: AC
Inductive sensor
NJ40-FP-SN-B1-P1-Y024207 Series: Rectangular type, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 2-wire, Installation: flush, Type of voltage: DC
Inductive sensor
NJ40-FP-SN-P1 Series: Rectangular type, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40-FP-SN-P4 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 40 mm, Connection type: 1/2 NPT terminal compartment, wire cross-section ≤ 2.5 mm2, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ40P-FP-A2-P1 Series: Rectangular type, Housing material: PBT, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ50-FP-A-P1 Series: Rectangular type, Housing material: PBT, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ50-FP-E-P1 Series: Rectangular type, Housing material: PBT, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor倍加福传感器官网 倍加福中国官方网站 施耐德接近开关选型 接近开关 倍加福接近开关选型
倍加福 倍加福官网 接近开关原理 倍加福接近开关样本 倍加福接近开关型号
NJ50-FP-E-P4-V1 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: V1 connector (M12 x 1), 4-pin, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ50-FP-N-P1 Series: Rectangular type, Housing material: PBT, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 2-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ50-FP-N-P4 Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: screw terminals, Output type: 2-wire, Installation: not embeddable, Type of voltage: DC
Inductive sensor
NJ60-FP-A2-P1-Y237069 Series: Rectangular type, Housing material: POM, Rated operating distance: 60 mm, Connection type: screw terminals, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ60-FP-A2-P1-Y237070 Series: Rectangular type, Housing material: POM, Rated operating distance: 60 mm, Connection type: screw terminals, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ60-FP-E2-P2 Series: Rectangular type, Housing material: POM, Rated operating distance: 60 mm, Connection type: screw terminals, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NJ60-FP-E2-P2-V1 Housing material: POM, Rated operating distance: 60 mm, Connection type: Device connector M12 x 1 , 4-pin, Output type: 3-wire, Installation: not embeddable, Type of voltage: DC
Inductive sensor
NRB50-FP-A2-C-P3-V1 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 4-wire, Installation: flush, Type of voltage: DC
Inductive sensor
NRB50-FP-A2-P3-V1 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 4-wire, Installation: flush, Type of voltage: DC
Inductive sensor
NRB50-FP-E2-C-P3-V1 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 3-wire, Installation: flush, Type of voltage: DC
Inductive sensor
NRB50-FP-E2-P3-V1 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 50 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 3-wire, Installation: flush, Type of voltage: DC
Inductive sensor
NRN40-L3K-A2-C-V1 Series: VariKont L ®, Housing material: GD-ZnAl4Cu1, coated
mounting flange PA6-GF35, Rated operating distance: 40 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NRN40-L3K-A2-V1 Series: VariKont L ®, Housing material: GD-ZnAl4Cu1, coated
mounting flange PA6-GF35, Rated operating distance: 40 mm, Connection type倍加福传感器官网 倍加福中国官方网站 施耐德接近开关选型 接近开关 倍加福接近开关选型
倍加福 倍加福官网 接近开关原理 倍加福接近开关样本 倍加福接近开关型号: Connector M12 x 1 , 4-pin, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NRN40-L3K-E2-C-V1 Series: VariKont L ®, Housing material: GD-ZnAl4Cu1, coated
mounting flange PA6-GF35, Rated operating distance: 40 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NRN40-U1-A2 Series: VariKont ®, Housing material: PA/metal with epoxy powder coating, Rated operating distance: 40 mm, Connection type: screw terminals, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NRN40-U1-E2-V1 Series: VariKont ®, Housing material: PA/metal with epoxy powder coating, Rated operating distance: 40 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NRN75-FP-A2-C-P3-V1 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 75 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NRN75-FP-A2-P3 Series: Rectangular type, Housing material: PBT, Rated operating distance: 75 mm, Connection type: screw terminals, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NRN75-FP-A2-P3-V1 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 75 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 4-wire, Installation: non-flush, Type of voltage: DC
Inductive sensor
NRN75-FP-E2-C-P3-V1 Series: Rectangular type, Housing material: PBT/metal, Rated operating distance: 75 mm, Connection type: Connector M12 x 1 , 4-pin, Output type: 3-wire, Installation: non-flush, Type of voltage: DC
|