产品阐述 |
Single head system |
General specifications |
Sensing range |
80 ... 2000 mm |
Adjustment range |
100 ... 2000 mm |
Unusable area |
0 ... 80 mm |
Standard target plate |
100 mm x 100 mm |
Transducer frequency |
approx. 175 kHz |
Response delay |
minimum (EM; NONE): ≤50 ms (2 measuring cycles)
factory setting (EM, MXN, 5, 2): ≤150 ms (6 measuring cycles)
dynamic (EM, DYN): ≤75 ms (3 measuring cycles) |
Indicators/operating means |
LED green |
continuous: object in the measuring window
flashing: object outside the measuring window |
LED red |
error (e. g. interference level too high) |
Electrical specifications |
Operating voltage |
10 ... 30 V DC
ripple ± 10 %SS
|
Power consumption |
≤ 2 W (all relays pulled-in, current output 20 mA)
no-load power consumption ≤ 0.7 W |
Interface |
Interface type |
RS 232, 9600 bit/s, no parity, 8 data bits, 1 stop bit |
Output |
Output type |
2 relay outputs, 1 analog output 4 ... 20 mA |
Resolution |
0.6 mm |
Deviation of the characteristic curve |
< 0.2 % of full-scale value |
Repeat accuracy |
≤ 0.1 % of full-scale value |
Range hysteresis |
0 ... 15 % programmable with ULTRA 2001 |
Load impedance |
current output:
≤ 500 Ω at UB ≥ 17V
≤ 200 Ω at UB < 17V |
Contact loading |
60 V DC / 1 A (max. 24 W DC), ohmic |
Life span |
electrical: 3 x 105 switching cycles at resistive load
(1 A / 24 V DC)
mechanical: 107 switching cycles |
Temperature influence |
≤ 2 % of full-scale value |
Approvals and certificates |
UL approval |
cULus Listed, General Purpose |
CSA approval |
cCSAus Listed, General Purpose |
Ambient conditions |
Ambient temperature |
-25 ... 70 °C (-13 ... 158 °F) |
Storage temperature |
-40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Connection type |
Connector M12 x 1 , 8-pin
screen connected to pin 8 |
Protection degree |
IP65 |
Material |
|
|
Housing |
PBT |
|
Transducer |
epoxy resin/hollow glass sphere mixture; polyurethane foam |
Mass |
290 g |