产品阐述 |
Single head system |
General specifications |
Sensing range |
80 ... 2000 mm |
Adjustment range |
120 ... 2000 mm |
Unusable area |
0 ... 80 mm |
Standard target plate |
100 mm x 100 mm |
Transducer frequency |
approx. 180 kHz |
Response delay |
approx. 150 ms |
Indicators/operating means |
LED green |
solid: Power-on
flashing: program function object detected |
LED yellow |
solid: switching state switch output
flashing: program function |
LED red |
normal operation: "fault"
program function: no object detected |
Electrical specifications |
Operating voltage |
10 ... 30 V DC , ripple 10 %SS |
No-load supply current |
≤ 50 mA |
Input/Output |
Synchronization |
bi-directional
0 level -UB...+1 V
1 level: +4 V...+UB
input impedance: > 12 KOhm
synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms |
Synchronization frequency |
|
|
Common mode operation |
max. 30 Hz |
|
Multiplex operation |
≤ 30 Hz / n , n = number of sensors , n ≤ 5
|
Input |
Input type |
1 program input,
operating range 1: -UB ... +1 V, operating range 2: +4 V ... +UB
input impedance: > 4.7 kΩ; program pulse: ≥ 1 s |
Output |
Output type |
1 switch output PNP , Normally open/closed , programmable |
Rated operating current |
200 mA , short-circuit/overload protected |
Voltage drop |
≤ 2.5 V |
Repeat accuracy |
≤ 0.5 % of switching point |
Switching frequency |
≤ 3.3 Hz |
Range hysteresis |
1 % of the set operating distance |
Temperature influence |
< 2 % of far switch point |
Approvals and certificates |
UL approval |
cULus Listed, General Purpose |
CSA approval |
cCSAus Listed, General Purpose |
Ambient conditions |
Ambient temperature |
-25 ... 70 °C (-13 ... 158 °F) |
Storage temperature |
-40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Connection type |
Connector M12 x 1 , 5-pin |
Protection degree |
IP65 |
Material |
|
|
Housing |
nickel plated brass; plastic components: PBT |
|
Transducer |
epoxy resin/hollow glass sphere mixture; polyurethane foam |
Mass |
140 g |