General specifications |
Switching element function |
NAMUR, NC |
Rated operating distance |
40 mm |
Installation |
non-flush |
Output polarity |
DC |
Assured operating distance |
0 ... 32.4 mm |
Reduction factor rAl |
0.31 |
Reduction factor rCu |
0.3 |
Reduction factor r304 |
0.74 |
Nominal ratings |
Nominal voltage |
8.2 V (Ri approx. 1 kΩ) |
Switching frequency |
0 ... 150 Hz |
Hysteresis |
typ. 5 % |
Reverse polarity protection |
reverse polarity protected |
Short-circuit protection |
yes |
Current consumption |
|
|
Measuring plate not detected |
≥ 2.2 mA |
|
Measuring plate detected |
≤ 1 mA |
Switching state indication |
LED, yellow |
Functional safety related parameters |
MTTFd |
1670 a |
Mission Time (TM) |
20 a |
Diagnostic Coverage (DC) |
0 % |
Approvals and certificates |
UL approval |
cULus Listed, General Purpose |
CSA approval |
cCSAus Listed, General Purpose |
CCC approval |
CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature |
-25 ... 100 °C (-13 ... 212 °F) |
Storage temperature |
-40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications |
Connection type |
Connector M12 x 1 , 4-pin |
Housing material |
PA |
Sensing face |
PA |
Housing diameter |
|
Protection degree |
IP69K |
General information |
Use in the hazardous area |
see instruction manuals |
|
Category |
1G; 2G; 3G; 3D |