General specifications |
Switching element function |
PNP NO/NC |
Rated operating distance |
25 mm |
Installation |
flush mountable |
Output polarity |
DC |
Assured operating distance |
0 ... 20 mm |
Reduction factor rAl |
0.5 |
Reduction factor rCu |
0.5 |
Reduction factor r304 |
0.6 ... 1 |
Mounting angle |
Al |
Amplifier housing |
Stainless steel |
Nominal ratings |
Operating voltage |
10 ... 30 V |
Switching frequency |
0 ... 20 Hz |
Hysteresis |
0.3 ... 5 typ. 2 % |
Reverse polarity protection |
reverse polarity protected |
Short-circuit protection |
pulsing |
Voltage drop |
≤ 3 V |
Operating current |
0 ... 200 mA |
No-load supply current |
≤ 25 mA |
Switching state indication |
Multihole-LED, yellow |
Functional safety related parameters |
MTTFd |
7515 a |
Mission Time (TM) |
20 a |
Diagnostic Coverage (DC) |
0 % |
Approvals and certificates |
UL approval |
cULus Listed, General Purpose, Class 2 Power Source |
CCC approval |
CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature |
0 ... 250 °C (32 ... 482 °F) |
Mechanical specifications |
Connection type |
Connector M12 x 1 , 4-pin |
Cable version |
PFA cable, with armour of stainless steel |
Core cross-section |
3 x 0.34 , screened |
Housing material |
PTFE / Al / 1.4305 / AISI 303 |
Sensing face |
PTFE |
Protection degree |
amplifier IP67
sensor IP40 |
Note |
- amplifier 0 °C ... 70 °C
- r1.4305 dep. on thickness of measurement plate d:
r1.4305 = 1 for d < 1mm
Additional accessory: Protective cover SH-F35 is available for use in areas where there is moisture and as a means of mechanical protection. |