General specifications |
Sensing range |
20 ... 60 mm , optimal distance: 45 mm |
Transducer frequency |
255 kHz |
Indicators/operating means |
LED green |
Display: readiness |
LED yellow |
Display: splice detected |
LED red |
Indication: No sheet detected (Air) |
Electrical specifications |
Operating voltage |
18 ... 30 V DC , ripple 10 %SS |
No-load supply current |
< 60 mA |
Input |
Input type |
TEACH-IN input
0-level: -UB ... -UB + 1V
1-level: +UB - 1 V ... +UB |
Pulse length |
≥ 500 ms |
Impedance |
≥ 10 kΩ |
Output |
Output type |
2 switch outputs PNP, NC |
Rated operating current |
2 x 100 mA , short-circuit/overload protected |
Voltage drop |
≤ 3 V |
Switch-on delay |
≤ 600 µs |
Switch-off delay |
≤ 600 µs |
Pulse extension |
≥ 120 ms programmable |
Approvals and certificates |
UL approval |
cULus Listed, General Purpose |
CSA approval |
cCSAus Listed, General Purpose |
Ambient conditions |
Ambient temperature |
0 ... 60 °C (32 ... 140 °F) |
Storage temperature |
-40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications |
Connection type |
cable PVC , 2 m |
Core cross-section |
0.14 mm2 |
Protection degree |
IP67 |
Material |
|
|
Housing |
nickel plated brass; plastic components: PBT |
|
Transducer |
epoxy resin/hollow glass sphere mixture; polyurethane foam |
Mass |
150 g |