产品阐述 |
Single head system |
General specifications |
Sensing range |
15 ... 120 mm |
Adjustment range |
20 ... 120 mm |
Unusable area |
0 ... 15 mm |
Standard target plate |
10 mm x 10 mm |
Transducer frequency |
approx. 850 kHz |
Response delay |
approx. 27 ms |
Indicators/operating means |
LED yellow |
solid yellow: object in the evaluation range
yellow, flashing: program function, object detected |
LED red |
solid red: Error
red, flashing: program function, object not detected |
Electrical specifications |
Operating voltage |
10 ... 30 V DC , ripple 10 %SS |
No-load supply current |
≤ 30 mA |
Input |
Input type |
1 program input
lower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB
input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s |
Output |
Output type |
1 analog output 4 ... 20 mA |
Resolution |
0.17 mm
|
Deviation of the characteristic curve |
± 1 % of full-scale value |
Repeat accuracy |
± 0.5 % of full-scale value |
Load impedance |
0 ... 300 Ohm |
Temperature influence |
± 1.5 % of full-scale value |
Approvals and certificates |
UL approval |
cULus Listed, General Purpose |
CSA approval |
cCSAus Listed, General Purpose |
Ambient conditions |
Ambient temperature |
-25 ... 70 °C (-13 ... 158 °F) |
Storage temperature |
-40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Connection type |
Connector M12 x 1 , 4-pin |
Protection degree |
IP67 |
Material |
|
|
Housing |
brass, nickel-plated |
|
Transducer |
epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT |
Mass |
25 g |