General specifications |
Signal type |
Analog output |
Supply |
Connection |
Power Rail or terminals 14+, 15- |
Rated voltage |
10 ... 35 V DC |
Ripple |
within the supply tolerance |
Power loss |
0.8 W |
Power consumption |
1 W at 20 mA |
Input |
Connection |
terminals 7-, 8+ |
Voltage drop |
approx. 2.5 V or internal resistance 125 Ω at 20 mA |
Input resistance |
≤ 2.5 V, equivalent to 125 Ω at 20 mA |
Ripple |
50 µArms |
Current |
4 ... 20 mA limited to approx. 24 mA |
Output |
Connection |
terminals 1+, 2- |
Current |
4 ... 20 mA |
Load |
0 ... 700 Ω |
Voltage |
≥ 14 V at 20 mA |
Transfer characteristics |
Rise time |
< 100 µs , 10 ... 90 % step change |
Directive conformity |
Electromagnetic compatibility |
|
|
Directive 2004/108/EC |
EN 61326-1:2006 |
Conformity |
Electromagnetic compatibility |
NE 21:2006 |
Protection degree |
IEC 60529:2001 |
Ambient conditions |
Ambient temperature |
-20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications |
Protection degree |
IP20 |
Mass |
approx. 150 g |
Dimensions |
20 x 119 x 115 mm (0.8 x 4.7 x 4.5 in) , housing type B2 |
Mounting |
on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with Ex-areas |
EC-Type Examination Certificate |
BAS 00 ATEX 7240 , for additional certificates see www.pepperl-fuchs.com |
|
Group, category, type of protection |
II (1)GD, I (M1), [Ex ia] IIC, [Ex iaD], [Ex ia] I (-20 °C ≤ Tamb ≤ 60 °C) [circuit(s) in zone 0/1/2] |
Statement of conformity |
TÜV 99 ATEX 1499 X , observe statement of conformity |
|
Group, category, type of protection, temperature class |
II 3G Ex nA II T4 [device in zone 2] |
Directive conformity |
|
|
Directive 94/9/EC |
EN 60079-0:2009, EN 60079-11:2007, EN 60079-15:2005, EN 61241-11:2006 |
International approvals |
UL approval |
|
|
Control drawing |
116-0173 (cULus) |
IECEx approval |
IECEx BAS 04.0014 |
|
Approved for |