General specifications |
Detection type |
photoelectric sampling |
Pulse count |
max. 5000 |
Functional safety related parameters |
MTTFd |
140 a |
Mission Time (TM) |
20 a |
L10h |
70 E+9 at 6000 rpm |
Diagnostic Coverage (DC) |
0 % |
Electrical specifications |
Operating voltage |
10 ... 30 V DC |
No-load supply current |
max. 50 mA |
Output |
Output type |
RS 422, incremental |
Load current |
max. per channel 20 mA , conditionally short-circuit proof (not with Ub), reverse polarity protected |
Output frequency |
max. 200 kHz |
Rise time |
100 ns |
Connection |
Cable |
∅7.8 mm, 6 x 2 x 0.14 mm2, 1 m |
Standard conformity |
Protection degree |
DIN EN 60529, IP54 |
Climatic testing |
DIN EN 60068-2-78 , no moisture condensation |
Emitted interference |
EN 61000-6-4:2007 |
Noise immunity |
EN 61000-6-2:2005 |
Shock resistance |
DIN EN 60068-2-27, 100 g, 3 ms |
Vibration resistance |
DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz |
Approvals and certificates |
UL approval |
cULus Listed, General Purpose, Class 2 Power Source |
Ambient conditions |
Operating temperature |
|
|
Glass disk |
-5 ... 80 °C (23 ... 176 °F) , movable cable
-20 ... 80 °C (-4 ... 176 °F), fixed cable |
|
Plastic disk |
-5 ... 60 °C (23 ... 140 °F) , movable cable
-20 ... 60 °C (-4 ... 140 °F), fixed cable |
Storage temperature |
|
|
Glass disk |
-40 ... 85 °C (-40 ... 185 °F) |
|
Plastic disk |
-40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications |
Material |
|
|
Housing |
powder coated aluminum |
|
Flange |
3.1645 aluminum |
|
Shaft |
Stainless steel 1.4305 / AISI 303 |
Mass |
approx. 290 g |
Rotational speed |
max. 6000 min -1 |
Moment of inertia |
≤ 40 gcm2 |
Starting torque |
≤ 1.5 Ncm |
Shaft load |
|
|
Angle offset |
1 ° |
|
Axial offset |
max. 1 mm |