General specifications |
Detection type |
photoelectric sampling |
Pulse count |
max. 1500 |
Functional safety related parameters |
MTTFd |
810 a |
Mission Time (TM) |
20 a |
L10h |
50 E+9 at 3000 rpm |
Diagnostic Coverage (DC) |
0 % |
Electrical specifications |
Operating voltage |
4.75 ... 30 V DC
5 V DC for RS 422 |
No-load supply current |
max. 55 mA |
Output |
Output type |
push-pull, incremental (RS 422, incremental) |
Voltage drop |
≤ 2.5 V (< 2.5 V) |
Load current |
max. per channel 30 mA , short-circuit protected (max. per channel 20 mA, conditionally short-circuit proof) |
Output frequency |
max. 100 kHz (max. 100 kHz) |
Rise time |
980 ns (225 ns) |
De-energized delay |
980 ns (225 ns) |
Connection |
Cable |
∅6 mm, 8 x 0.14 mm2, 0.5 m, UL-Style 2571 |
Standard conformity |
Protection degree |
DIN EN 60529, IP54 |
Climatic testing |
DIN EN 60068-2-3, no moisture condensation |
Emitted interference |
EN 61000-6-4:2007 |
Noise immunity |
EN 61000-6-2:2005 |
Shock resistance |
DIN EN 60068-2-27, 100 g, 6 ms |
Vibration resistance |
DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz |
Approvals and certificates |
UL approval |
cULus Listed, General Purpose, Class 2 Power Source |
Ambient conditions |
Operating temperature |
|
|
Nickel disk |
-10 ... 70 °C (14 ... 158 °F) |
Storage temperature |
|
|
Nickel disk |
-40 ... 80 °C (-40 ... 176 °F) |
Mechanical specifications |
Material |
|
|
Housing |
aluminum, blank |
|
Flange |
3.1645 aluminum |
|
Shaft |
Stainless steel 1.4305 / AISI 303 |
Mass |
approx. 290 g |
Rotational speed |
max. 6000 min -1 |
Moment of inertia |
≤ 40 gcm2 |
Starting torque |
≤ 2.5 Ncm |
Shaft load |
|
|
Angle offset |
1 ° |
|
Axial offset |
max. 1 mm |