General specifications |
Switching element function |
PNP NO |
Rated operating distance |
20 mm |
Installation |
flush |
Output polarity |
DC |
Assured operating distance |
0 ... 16.2 mm |
Reduction factor rAl |
0.33 |
Reduction factor rCu |
0.31 |
Reduction factor r304 |
0.74 |
Reduction factor rBrass |
0.41 |
Nominal ratings |
Operating voltage |
10 ... 30 V DC |
Switching frequency |
0 ... 150 Hz |
Hysteresis |
typ. 5 % |
Reverse polarity protection |
reverse polarity protected |
Short-circuit protection |
pulsing |
Voltage drop |
≤ 2 V |
Operating current |
0 ... 200 mA |
Off-state current |
0 ... 0.5 mA |
No-load supply current |
≤ 20 mA |
Operating voltage display |
LED, green |
Switching state indication |
LED, yellow |
Functional safety related parameters |
MTTFd |
1460 a |
Mission Time (TM) |
20 a |
Diagnostic Coverage (DC) |
0 % |
Approvals and certificates |
Protection class |
II |
|
Rated insulation voltage |
253 V |
|
Design-impulse-voltage withstand |
4000 V |
UL approval |
cULus Listed, General Purpose |
CSA approval |
cCSAus Listed, General Purpose |
CCC approval |
CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature |
-25 ... 85 °C (-13 ... 185 °F) |
Storage temperature |
-40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Connection type |
Connector M12 x 1 , 4-pin |
Housing material |
PA |
Sensing face |
PA |
Housing diameter |
|
Protection degree |
IP69K |
Mass |
130 g |