商铺名称:中山朗立电气有限公司
联系人:游小姐(小姐)
联系手机:
固定电话:
企业邮箱:lixun98@126.com
联系地址:中山市港口镇兴港南路17号153卡
邮编:528400
联系我时,请说是在电子快手网上看到的,谢谢!
北市区SANIL开关SB-31L,5m,Mos,Relay,2m,中山立讯电气有限公司工厂直售韩国SYM(ShinYeong Mechatronics )电磁阀
BP-KV100 BP-KV100B BP-KV190 BP-KV200 BP-KV200B BP-KV290 BP-KV300 BP-KV300B BP-KV390 CA2-V1 CA2-V2 CA2-V4 CA2-V4-10 CA2-V4-15 CA2-V4-30 CA2-V4-6 EP-KV100 EP-KV100B KV100B-BASE KV100-G KV100-GS KV110-1E-C4 KV110-1E-C6 KV110-1E-M5 KV110-2E-C4 KV110-2E-C6 KV110-2E-M5 KV110-2L-M5 KV110-3E-C4 KV110-3E-C6 KV110-3E-M5 KV110-3L-C4 KV110-3L-C6 KV110-3L-M5 KV110-3P-C4 KV110-3P-C6 KV110-3P-M5 KV110-4E-C4 KV110-4E-C6 KV110-4E-M5 KV110-4E-M5-X3 KV110-4EN-C4 KV110-4EN-M5 KV110-4ES-C4 KV110-4ES-M5 KV110-4EZ-C4 KV110-4EZ-M5 KV110-4L-C4 KV110-4L-C6 KV110-4L-M5 KV110-4P-C4 KV110-4P-C6 KV110-4P-M5 KV110-4PN-C4 KV110-4PN-C6 KV110-4Q-C4 KV110-4Q-C6 KV110-4Q-M5 KV110-6E-M5 KV110B-1E KV110B-1E-01 KV110B-2E KV110B-2E-01 KV110B-3E KV110B-3E-01 KV110B-3P KV110B-4E KV110B-4E-01 KV110B-4L KV110B-4L-01 KV110B-4P KV110B-4P-01 软启动器只是改变电源电压,相当于降压起动器。变频器要比软启动器复杂得多,价格也贵得多。变频器也有软启动功能,是通过改变电源频率实现。高压启动器和低压启动器的区别软启动器主回路采用晶闸管,通过逐步改变晶闸管的导通角来抬升电压,完成启动过程,这是软启动器的基本原理。在低压软启动器市场,产品繁多,但是高压软启动器产品还是比较少。高压软启动器与低压软启动器基本原理一样,但是高压软启动器与低压软启动器相比,有些地方存在着其特殊性:高压软启动器在高压环境下工作,各种电气元器件的绝缘性能一定要好,电子芯片的抗干扰能力要强。高压软起动器组成电气柜时,电气元器件的布局以及与高压软启动器与其它电气设备的连接也是非常重要的。KV110B-4Q KV110B-4Q-01 KV120-1E-M5 KV120-2E-C4 KV120-2E-C6 KV120-2E-M5 KV120-3E-C4 KV120-3E-C6 KV120-3E-M5 KV120-3P-C4 KV120-3P-C6 KV120-3P-M5 KV120-4E-C4 KV120-4E-C6 KV120-4E-M5 KV120-4EN-M5 KV120-4L-C4 KV120-4L-C6 KV120-4L-M5 KV120-4P-C4 KV120-4P-C6 KV120-4P-M5 KV120-4PN-C4 KV120-4Q-C4 KV120-4Q-C6 KV120-4Q-M5 KV120-6E – ??? KV120-6E-??? KV120B-1E KV120B-1E-01 KV120B-3E KV120B-3P KV120B-4E KV120B-4E-01 KV120B-4L KV120B-4L-01 KV120B-4P KV120B-4P-01 KV120B-4Q KV120B-4Q-01 KV120B-6E KV130-1E-C6 KV130-1E-M5 KV130-2E-M5 KV130-3L-C4 KV130-3L-C6 KV130-3L-M5 KV130-3P-C4 KV130-3P-M5 KV130-4E-C4 KV130-4E-C6 KV130-4E-M5 KV130-4EN-C4 KV130-4L-C4 KV130-4L-C6 KV130-4L-M5 KV130-4P-C4 KV130-4P-C6或可采用高速可控硅(晶闸管)。关于连续峰值开路电压VDRM在电源不正常的情况下,可控硅(晶闸管)两端的电压会超过连续峰值开路电压VDRM的值,此时可控硅(晶闸管)的漏电流增大并击穿导通。如果负载能允许很大的浪涌电流,那么硅片上局部的电流密度就很高,使这一小部分先导通。导致芯片烧毁或损坏。另外白炽灯,容性负载或短路保护电路会产生较高的浪涌电流,这时可外加滤波器和钳位电路来防止尖峰(毛刺)电压加到双向可控硅(晶闸管)上[2]。
KV130-4P-M5 KV130-4Q-C4 KV130-4Q-C6 KV130-4Q-M5 KV130B-1E KV130B-2E KV130B-3E KV130B-4E KV130B-4E-01 KV130B-4L KV130B-4L-01 KV130B-4P KV130B-4P-01 KV130B-4Q KV130B-4Q-01 KV130B-6E KV140-1E-M5 KV140-2E-C4 KV140-2E-M5 KV140-3E-C6 KV140-3E-??? KV140-4E-C4 KV140-4E-C6 KV140-4E-M5 KV140-4L-C4 KV140-4L-C6 KV140-4L-M5 KV140-4P-C4 KV140-4P-C6 KV140-4P-M5 KV140-4Q-C4 KV140-4Q-C6 KV140-4Q-M5 KV140B-4E KV140B-4E-01 KV140B-4L KV140B-4L-01 KV140B-4P KV140B-4P-01 KV140B-4Q KV140B-4Q-01 KV150-2E-M5 KV150-2E-??? KV150-4E-C4 KV150-4E-C6 KV150-4E-M5 KV150-4L-C4 KV150-4L-C6 KV150-4L-M5 KV150-4P-C4 KV150-4P-C6
中山立讯电气有限公司工厂直售韩国SYM(ShinYeong Mechatronics )电磁阀
KV150-4P-M5 KV150-4Q-C4 KV150-4Q-C6 KV150-4Q-M5 KV150B-4E KV150B-4E-01 KV150B-4L KV150B-4L-01 KV150B-4P KV150B-4P-01 KV150B-4Q KV150B-4Q-01 KV200B-BASE KV200-G KV200-GS KV200-S KV210-1E-01 KV210-1E-C4 KV210-1E-C6 KV210-1E-C8 KV210-1L-01 KV210-1L-C4 KV210-1L-C6 KV210-2E-01 KV210-2E-C4 KV210-2E-C6 KV210-2E-C8 KV210-2L-01 KV210-2L-C4 KV210-2L-C6 KV210-3E-01 KV210-3E-C4 KV210-3E-C8 KV210-3E-V6 KV210-3P-01 KV210-3P-C4 KV210-3P-C6 KV210-3P-C8 KV210-4E-01 KV210-4E-C4 KV210-4E-C6 KV210-4E-C8 KV210-4EN-01 KV210-4L-01 KV210-4L-C4 KV210-4L-C6 KV210-4P-01 KV210-4P-C4 KV210-4P-C6 KV210-4Q-01 KV210-4Q-C4 KV210-4Q-C6 KV210B-1E KV210B-1E-02 KV210B-1L KV210B-2E KV210B-2E-02 KV210B-2L KV210B-2L-02 KV210B-3E KV210B-4E它是旋转180°后的二次电流向量与一次电流向量之间的相位差。规定二次电流向量超前于一次电流向量δ为正值,反之为负值,用分(’)为计算单位。2.10热稳定及动稳定倍数:电力系统故障时,电流互感器受到由于短路电流引起的巨大电流的热效应和电动力作用,电流互感器应该有能够承受而不致受到破坏的能力,这种承受的能力用热稳定和动稳定倍数表示。热稳定倍数是指热稳定电流1s内不致使电流互感器的发热超过允许限度的电流与电流互感器的额定电流之比。动稳定倍数是电流互感器所能承受的电流瞬时值与其额定电流之比。类型区分编辑按用途分类按照用途不同,电流互感器大致可分为两类[4]:测量用电流互感器(或电流互感器的测量绕组):在正常工作电流范围内。 KV210B-4E-02 KV210B-4L KV210B-4L-02 KV210B-4P KV210B-4P-02 KV210B-4Q KV210B-4Q-02 KV210B-6P KV210B-6P-02 KV220-1E-01 KV220-1E-C6 KV220-2E-01 KV220-2E-C4 KV220-2E-C6 KV220-2L-01 KV220-2L-C4 KV220-2L-C6 KV220-3E-01 KV220-3E-C4 KV220-3E-C6 KV220-4E-01 KV220-4E-C4 KV220-4E-C6 KV220-4E-C8 KV220-4EN-01 KV220-4L-01 KV220-4L-C4 KV220-4L-C6 KV220-4P-01 KV220-4P-C4 KV220-4P-C6 KV220-4Q-01 KV220-4Q-C4 KV220-4Q-C6 KV220B-1E KV220B-2E KV220B-4E KV220B-4E-02 KV220B-4L KV220B-4L-02 KV220B-4P管压降(通态平均电压)为0.6---0.7V的普通型可控硅。综上所述,小结如下:(1)可控硅一般做成螺栓形和平板形,有三个电极,用硅半导体材料制成的管芯由PNPN四层组成(2)可控硅由关断转为导通必须同时具备两个条件:(1〕受正向阳极电压;(2)受正向门极电压。(3)可控硅导通后,当阳极电流小干维持电流In时.可控硅关断。(4)可控硅的特性主要是:1.阳极伏安特性曲线,2.门极伏安特性区。(5)应在额定参数范围内使用可控硅。选择可控硅主要确定两个参致:主要参数编辑电流⒈额定通态电流(IT)即稳定工作电流,俗称电流。常用可控硅的IT一般为一安到几十安。⒉反向重复峰值电压(VRRM)或断态重复峰值电压(VDRM)。 KV220B-4P-02 KV220B-4Q KV220B-4Q-02 KV230-1E-01 KV230-1E-C4 KV230-1E-C6 KV230-2E-02 KV230-2E-C4 KV230-2E-C6 KV230-3E-01 KV230-3E-C4 KV230-3E-C6 KV230-3P-01 KV230-3P-C4 KV230-3P-C6 KV230-4E-01 KV230-4E-C4 KV230-4E-C6 KV230-4E-C8 KV230-4L-01 KV230-4L-C4 KV230-4L-C6 KV230-4P-01 KV230-4P-C4 KV230-4P-C6 KV230-4Q-01 KV230-4Q-C4 KV230-4Q-C6 KV230B-1E KV230B-1E-02 KV230B-2E KV230B-4E KV230B-4E-02 KV230B-4L KV230B-4L-02 KV230B-4P KV230B-4P-02 KV230B-4Q KV230B-4Q-02 KV240-1E-01 KV240-1E-C4 KV240-1E-C6 KV240-2E-01 KV240-2E-C4 KV240-2E-C6 KV240-4E-01 KV240-4E-C4 b)当I/Is>2时,平均误差不大于5%+30ms。整定方法起动电流整定:起动电流整定开关为左一组拨码开关(共两个),左面一个表示1A级,右面一个表示0.1A级。若其值为5和6,则其整定值为5.6A。注意其范围为无辅助电压产品2-9.9A,级差是0.1A级。反时限特性曲线K值整定:K值整定开关为左第三组拨码开关(共二个),左边一个为表示1级;右边一个表示0.1级。本产品K值整定范围为0.1~9.9,(举例)比如其值设定为5.0,过流动作值设定为5.0,输入实际电流为30A时那么它的延时时间为13.5秒,但其速断倍数值应设定为6倍以上。速动倍数整定:速动倍数选择开关为左第二组拨码开关。
所以对大容量变频器更加有效。还可以用隔离板把本体和散热器隔开,使散热器的散热不影响到变频器本体。这样效果也很好。注意:变频器散热设计中都是以垂直安装为基础的,横着放散热会变差的!冷却风扇一般功率稍微大一点的变频器,都带有冷却风扇。同时,也建议在控制柜上出风口安装冷却风扇。进风口要加滤网以防止灰尘进入控制柜。注意控制柜和变频器上的风扇都是要的,不能谁替代谁。其他关于散热的问题在海拔高于1000m的地方,因为空气密度降低,因此应加大柜子的冷却风量以改善冷却效果。理论上变频器也应考虑降容,1000m每-5%。但由于实际上因为设计上变频器的负载能力和散热能力一般比实际使用的要大,所以也要看具体应用。比方说在1500m的地方。